Millboard Envello Cladding Trims
Millboard Envello Cladding Perforated Closure TrimMillboard Envello Cladding Horizontal Starter TrimMillboard Envello Cladding Starter TrimPerforated Closure TrimHorizontal Starter TrimVertical Starter Trim

Millboard Envello Cladding Trims GT250 GP300

£6.00£17.00

Envello Cladding Fascia Board

Add a finishing touch to your Millboard Cladding project. With our specially designed edging profiles, the corners are dressed to make the whole project come together.

The corner profiles and fascia boards add distinction to corners of buildings, window reveals, door reveals, soffits and much more. Our trims are specially selected to fit our profile, for a faster and easier install

Perforated Closure Trim

Used to prevent insects and rodents getting into the ventilated cavity behind the boards, whilst allowing airflow. Fixed at the bottom of the cladding with the starter trim, also at the top on its own, as well as with the corner profiles. Fixed with the 20mm fixings.

How many do I need?

Needed at top and bottom of the cladding and any windows.  Also needed for just the top of any doors

To calculate the number of 3m perforated closure boards needed, you

Add together width of cladding area x 2 (accounts for top and bottom of structure), plus combined width of all windows x 2, plus combined width of all doors.  Divide this number by 3 (3m is length of closure boards) = number of perforated closure boards needed

eg a 10m wide structure, with two windows 1.2m wide and a 0.9m wide door would be a total of 25.7m

25.7 divided by 3 (length of perforated closure board) equates to 8.56 (so 9 perforated closure boards needed in total)

Horizontal Starter Trim

Trim used to start the cladding at the bottom of the trim, when the cladding is fitted horizontally. Fixed with the perforated closure and 20mm fixings.

How many do I need?

Needed at the bottom of the cladding

To calculate the number of 2.5m Horizontal Starter Trims needed, you

Add together width of cladding area.  Divide this number by 2.5 (2.5m is length of Horizontal Starter Trims) = number of Horizontal Starter Trims needed

eg a 10m wide structure would be a total of 10m

10 divided by 2.5 (length of Horizontal Starter Trim) equates to 4 (so 4 Horizontal Starter Trims needed in total)

Vertical Starter Trim

Used to start the cladding at the bottom of the trim, when the cladding is fixed vertically. Fixed with the perforated closure and 20mm fixings.

How many do I need?

Needed at the bottom of the cladding

To calculate the number of 2.5m Vertical Starter Trims needed, you

Add together width of cladding area.  Divide this number by 2.5 (2.5m is length of Vertical Starter Trims) = number of Vertical Starter Trims needed

eg a 10m wide structure would be a total of 10m

10 divided by 2.5 (length of Vertical Starter Trim) equates to 4 (so 4 Vertical Starter Trims needed in total)

Priced per length + vat
1+
£17.00
50+
£16.15
100+
£15.30
1+
£10.00
50+
£9.50
100+
£9.00
1+
£6.00
50+
£5.70
100+
£5.40

Product Description

Please note this product is only available for local delivery, or collection. ‘Local Delivery’ is within an approximate 80 mile radius of HP2 4ZB.

This product is not available for delivery via a courier and will not be processed if you select ‘Courier service’ as a delivery method